ERLUS E 58 SL
Technical data
Size: | aprox. 29.5 x 46.5 cm |
Gauge: | aprox. 32.5 - 35.5 cm |
Average cover width: | aprox. 24.3 cm |
Quantity required per m²: | from 11.5 Pieces |
Weight per m² in accordance with DIN 1055 incl. battens: | aprox. 0.55 kN/m² |
Real weight without battens: | aprox. 43,0 - 48,0 kg/m² |
Pallet capacity: | 240 Pieces |
Pallet weight: | aprox. 937 kg |
Bundle capacity: | 5 Pieces |
Hail resistance class: | 4 |
Gauge class: | 34,0 cm |
Average eaves gauge | aprox. 36 cm |
X (distance) in mm | Ridge connection tile1) | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Roof pitch in ° | 10° | 15° | 20° | 25° | 30° | 35° | 40° | 45° | 50° | 55° | 60° |
Ridge tile no. 15 | 60 | 55 | 50 | 45 | 45 | 45 | 40 | 40 | 45 | - | - |
Ridge ventilation tile no. 15 Lü | 70 | 65 | 60 | 60 | 55 | 50 | 50 | 45 | 45²⁾ | 45²⁾ | 40²⁾ |
Ridge tile no. 18 | 45 | 40 | 35 | 35 | 30 | 30 | 30 | 30 | 30 | 25 | 20 |
Ridge ventilation tile no. 19 Lü | 40 | 35 | 30 | 30 | 30 | 30 | 25 | 30 | 35 | - | - |
Ridge tile no. 21 | 40 | 35 | 30 | 30 | 25 | 25 | 25 | 25 | 25 | 25 | - |
X (distance) in mm | Standard tiles2) | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Roof pitch in ° | 10° | 15° | 20° | 25° | 30° | 35° | 40° | 45° | 50° | 55° | 60° |
Ridge tile no. 15 | 70 | 65 | 60 | 60 | 60 | 55 | 60 | 55 | 55 | - | - |
Ridge ventilation tile no. 15 Lü | 75 | 70 | 65 | 60 | 55 | 50 | - | - | - | - | - |
Ridge tile no. 18 | 50 | 45 | 45 | 45 | 30 | 30 | 30 | 30 | 30 | 25 | 20 |
Ridge ventilation tile no. 19 Lü | 50 | 40 | 35 | 35 | 30 | 30 | 25 | 30 | - | - | - |
Ridge tile no. 21 | 50 | 40 | 35 | 35 | 30 | 30 | 30 | 25 | 25 | - | - |
1) without aluminium ridge ventilation strap2) with aluminium ridge ventilation strap
Assignment of additional measures for the Ergoldsbacher E58 SL
According to the Central Association of German Roofers’ pamphlet on sub-roofs, sub-coverings and under-bracings, and the basic regulations of the Roofers’ Guild, regular roof pitch 20°, minimum roof pitch 10°, according to the generally accepted rules of technology.
Country-specific building standards and/or regulations must be adhered to, if no other contractual agreements have been made.
Increased demands due to
Use: of the attic level, especially for residential purposes (residential use equals two increased demands)
Construction: special roof shapes (e.g. butterfly roof), long spar lengths (longer than 10 meters), heavily structured roof shapes (e.g. due to valleys, gables, etc.)
Climate situation: exposed locations, extreme locations, areas with a lot of snow, special weather situations, areas with a lot of wind
Technical installations: On-roof or in-roof systems, air-conditioning systems, antenna systems, roof access systems, rooflight/skylight
systems, snow guard systems, etc.
Classification
Class 1: Waterproof sub-roof (1.1.)
Class 2: Rainproof sub-roof (1.2.)
Class 3: Seam and perforation secured under-bracing (2.1.) Seam and perforation secured sub-covering (3.1.)
Class 4: Welded or glued sub-covering (2.2.) Coated under-bracing made of strips of bitumen (2.3.) Seam-secured sub-covering (3.2.)
Class 5: Overlapped / tongue in groove sub-covering (2.4.)
Class 6: Under-bracing (3.3.)
roof pitch | min. req. | inc. dem. |
---|---|---|
≥ 20° | Class 5 | Class 4 |
from < 20° to ≥ 16° | Class 4 | Class 3 |
from < 16° to ≥ 12° | Class 3 | Class 2 |
from < 12° to ≥ 10° | Class 1 | Class 1 |
roof pitch | min. req. | inc. dem. |
---|---|---|
≥ 20° | Class 5 | Class 4 |
from < 20° to ≥ 16° | Class 4 | Class 3 |
from < 16° to ≥ 12° | Class 3 | Class 2 |
from < 12° to ≥ 10° | Class 1 | Class 1 |
These are the advantages of the
ERLUS E 58 SL
Wide colour range
Complete accessories including aluminium accessories from one source
Gauge class: 34,0 cm
Safe against storm and wind suction due to the hooked four-tile corner
Extremely easy to install due to the big slinding range
20° standard roof pitch
Sliding range 30 mm
Especially robust and break-proof